Improving the energy efficiency class: what really moves the letter
Christine Werker Energieberaterin (EEE) & Architektin
As of:
Your energy performance certificate shows an F, a G or an H, and you wonder what it takes to get away from it. This article is written for owners of a residential building who are about to renovate and want to know which measure actually moves a letter — and which does not.
The article first works out what the class depends on and how many kilowatt-hours lie between two letters. After that: which measures deliver how much of that, what changes nothing about the rating despite high costs, when the improvement shows up in the certificate and what a better class is worth in practice.
What does the energy efficiency class depend on at all?
On exactly one figure. Under § 86 (2) of the Building Modernisation Act (Gebäudemodernisierungsgesetz, GModG) the energy efficiency class (Energieeffizienzklasse) follows directly from the final energy consumption or final energy demand — not from the year of construction, not from the heating system, not from an expert’s assessment.1 The nine levels and their limits are set out in Annex 10; the calculation is in kilowatt-hours per square metre of usable floor area (Gebäudenutzfläche) and year.2 Which measures come into question at all and what the federal government contributes is set out in energy-efficient renovation and funding 2026.
The difference between usable floor area and living space (Wohnfläche) is not a detail here. If the usable floor area is not known, for residential buildings with up to two residential units and a heated basement it may be set at a flat 1.35 times the living space, and otherwise at 1.2 times (§ 82 (2)).3 The same number of kilowatt-hours spread over a larger area gives a smaller figure — so the reference area helps decide the letter. What the letter says on its own is explained in energy efficiency class of a house.
Energy efficiency classes for residential buildings (Annex 10 GModG), final energy per m² of usable floor area and year
- A+ up to 30 kWh/(m²·a)
- A up to 50 kWh/(m²·a)
- B up to 75 kWh/(m²·a)
- C up to 100 kWh/(m²·a)
- D up to 130 kWh/(m²·a)
- E up to 160 kWh/(m²·a)
- F up to 200 kWh/(m²·a)
- G up to 250 kWh/(m²·a) highlighted
- H over 250 kWh/(m²·a)
How many kilowatt-hours does a letter cost?
That is the question that comes before any list of measures — and the answer explains a common disappointment: the classes differ in width.
| Class | Upper limit | Width of the class |
|---|---|---|
| A+ | 30 | — |
| A | 50 | 20 |
| B | 75 | 25 |
| C | 100 | 25 |
| D | 130 | 30 |
| E | 160 | 30 |
| F | 200 | 40 |
| G | 250 | 50 |
| H | over 250 | open |
In the lower part of the scale the levels are therefore at their widest. Anyone who wants to get from the upper limit of G at 250 to the upper limit of D at 130 has to shed 120 kilowatt-hours per square metre and year permanently — that is the longest route across three classes that the scale knows. Anyone who starts further down in G needs correspondingly less. Anyone who starts at 248 kilowatt-hours needs 48 of them just to get out of G at all — and another 50 to reach E. Anyone who starts at 102 needs two to get a C.
From this follows a rule of thumb that comes before obtaining any quote: the distance to the next limit decides the benefit of a measure, not its size. Two houses with identical renovation can end up having gained one letter and three letters, simply because one was just above a limit and the other just below. Anyone who wants to know what a specific step delivers therefore first needs their own starting value and then the calculation — not the other way round.
From G to D on a single-family house
Starting point: 210 kilowatt-hours per square metre and year, class G. The target is class D, whose upper limit is 130.
210 − 130 = 80 kWh/(m²·a)
With 150 square metres of usable floor area, that is 12,000 kilowatt-hours a year that have to be saved permanently — around 38 per cent of previous consumption.
The figures have been chosen for illustration. In the certificate, the consumption-based determination adds weather adjustment and vacancy correction; both shift the result.
Result around 80 kWh/(m²·a) have to go — three classes
Which measure delivers how much?
Caution is called for here, for a reason that most overviews skip: there is no representative official statistic along the lines of “roof insulation delivers X kilowatt-hours”. What a component delivers depends on the year of construction, the type of construction, its share of the area and the condition of all the other components. Only calculations that disclose their reference building are reliable.
The non-profit advice organisation co2online publishes such a calculation for a single renovated single-family house — a building from 1923 in Falkensee whose consumption per square metre fell from 211 to 78 kilowatt-hours.8 The following shares are expressly not an average for the German building stock but the effect on this one house.
| Measure | Share of the saving |
|---|---|
| Insulating the façade | around 22 per cent |
| Replacing the heating system | around 17 per cent |
| Insulating the roof | around 15 per cent |
| Insulating the basement ceiling | around 10 per cent |
Two conclusions can be drawn from this, and both hold beyond the example building. The envelope contributes more in total than the heat generator — façade, roof and basement ceiling together are well above the heating’s share. And the big jumps come from combining measures, not from the single measure: the example house lost around 60 per cent of its heating energy consumption, but no single measure contributed more than just under a quarter of that.
What does not improve the class?
Three measures are regularly confused with a better rating.
A photovoltaic system. It acts on the annual primary energy demand: the yield is compared monthly with the electricity demand of the building services and deducted (§ 23).7 The energy efficiency class of a residential building, however, depends on final energy (§ 86 (2)).1 These are different quantities — the system lowers your electricity bill and your greenhouse gas balance, but it does not move the letter. The difference between the two figures is explained in primary energy demand and final energy demand.
Switching the type of certificate. A demand certificate (Bedarfsausweis) for the same building often turns out worse than a consumption certificate (Verbrauchsausweis), because it calculates with standardised user behaviour instead of actual behaviour. Anyone who switches the certificate type to get a better class may just as well get a worse one — and changes nothing about the building. Which type is suitable for what is explained in consumption certificate or demand certificate.
Economical heating alone. It has an effect in the consumption certificate, not in the demand certificate — the latter describes the building, not its use. And even in the consumption certificate the effect is limited, because the final energy consumption for heating is subject to weather adjustment (§ 82 (3)).3 A mild winter therefore does not improve the class.
In what order do you win the kilowatt-hours?
The technical principle is: first reduce demand, then replace the generator. The reason is sizing, not ideology — a heating system dimensioned before the insulation is too large afterwards, cycles more often and costs more to buy than it needs to.
For the logic of the classes there is a second reason that is often missing from advice sessions: measures on the envelope act on all future heating systems, a new generator acts only on today’s demand. Anyone who insulates the façade lowers the figure permanently; anyone who only replaces the heating lowers it once and starts from scratch again at the next step.
Three practical anchors set the order:
- Repairs that are due anyway come first. As soon as an external component is renewed, § 36 applies with the maximum values of Annex 7 — the scaffolding then goes up only once, and you have to meet the requirement anyway.45
- The largest areas first. What a component delivers depends, besides the U-value, above all on its share of the area. For a detached single-family house that is as a rule the external wall, for a mid-terrace house rather the roof and basement ceiling.
- Read the recommendations in your own certificate. Under § 84 (1) the issuer must name cost-effective improvements where they are possible.6 This list relates to the building and is therefore closer to your house than any general ranking.
When does the improvement show up in the certificate?
That depends on the type of certificate, and the difference is large enough to determine the order of your steps.
A demand certificate recalculates the building component by component. It reflects the new structural condition as soon as it is issued — yesterday’s insulation is in the certificate tomorrow.
A consumption certificate is based on bills from a consecutive period of 36 months that includes the most recent billing period; its end may not be more than 18 months ago (§ 82 (4)).3 A renovation completed in the last year counts there only with a third. Three billing periods pass before it has fully arrived.
From today's letter to the new one
-
Establish the starting value
The valid energy performance certificate states the figure. If there is none because the certificate has expired, the route begins with a new one.
-
Calculate target class and gap
Subtract the upper limit of the target class from Annex 10 — the result is the number of kilowatt-hours that has to disappear permanently.
-
Bundle measures
Envelope before heat generator, take advantage of repair dates. The combination brings the jump, not the single measure.
-
Secure funding, then commission
Application before the contract, contract with a funding clause. Which body is responsible depends on the component.
-
Have a new certificate issued
In the demand certificate the result shows immediately, in the consumption certificate after three billing periods.
An existing certificate does not become invalid because of the renovation, by the way. It runs its ten years and then describes an outdated condition — anyone who wants to show the better class has a new one issued. When that becomes due anyway is explained in energy performance certificate validity.
What is a better class worth in practice?
Three things, and only one of them is the saving on heating costs.
First, in the advertisement. For residential buildings the energy efficiency class is one of the five mandatory details in every commercial property advertisement — it appears there alongside the certificate type, the figure, the energy source and the year of construction. It is thus the first energy signal a prospective buyer or tenant sees, long before any viewing.
Second, in renovation planning. Under § 84 (1) the issuer must make recommendations for cost-effective improvements where they are possible.6 These recommendations appear in the certificate and are the usual way into subsidised advice — the certificate is thus not only a report card but the starting point.
Third, in the funding logic. The efficiency house levels (Effizienzhaus-Stufen) of federal funding are something different from the classes A+ to H: they measure the building against a calculated reference building, not against a fixed kilowatt-hour limit. Anyone who renovates to an efficiency house level almost always improves the class as well — but the proof runs via the level, not via the letter.
In both cases the starting value comes from the energy performance certificate; at Energieausweis Portal a demand certificate costs 119.90 €, a consumption certificate 69.90 €. You can order it via the form for the demand certificate; the price components are set out in what an energy performance certificate costs.
Frequently asked questions about improving the efficiency class
What owners most often ask about improving the class
Does a photovoltaic system improve the energy efficiency class?
Not for a residential building. Under § 86 (2) GModG the class follows directly from final energy; the yield of a photovoltaic system, by contrast, is deducted from the annual primary energy demand. These are different figures.
How many classes does a new heating system bring?
That cannot be said across the board. On the only disclosed example building, replacing the heating contributed around 17 per cent of the total saving — whether that turns into a letter depends on how far your figure is from the next class limit.
Is it enough to heat less?
Not in the demand certificate, because it calculates with standardised user behaviour. In the consumption certificate economical heating has an effect, but heating consumption is weather-adjusted — so a mild winter does not improve the class.
Do I have to have a new energy performance certificate issued after the renovation?
Only if calculations under § 38 are carried out for the whole building or a new occasion arises — sale, new letting, duty to display. It is still worthwhile voluntarily, because the old certificate shows the old condition.
Why is my demand certificate worse than my old consumption certificate?
Because it calculates the building and not its use. The demand certificate assumes standardised heating and ventilation behaviour; anyone who heats economically comes off better in the consumption certificate without the house being any better.
Conclusion: calculate the gap first, then bundle the measures
The energy efficiency class is not a judgement but a calculated quantity: a number of kilowatt-hours per square metre, compared with nine fixed limits. Anyone who wants to improve it first calculates the gap to the target class and thus knows how big the project really is — in the lower part of the scale that is up to 50 kilowatt-hours per level. The jump comes from combining envelope and heat generator, not from the single measure; and a photovoltaic system does not bring it at all, however sensible it may be otherwise.
Sources
- Building Modernisation Act (GModG), § 86 — Energy efficiency class of a residential building (version 09/2026) gesetze-im-internet.de ↩1 ↩2 ↩3
- Building Modernisation Act (GModG), Annex 10 — Energy efficiency classes of residential buildings (version 09/2026) gesetze-im-internet.de ↩1 ↩2 ↩3
- Building Modernisation Act (GModG), § 82 — Energy consumption certificate, determination of energy consumption (version 09/2026) gesetze-im-internet.de ↩1 ↩2 ↩3 ↩4 ↩5
- Building Modernisation Act (GModG), § 36 — Requirements for an existing building when altered (version 09/2026) gesetze-im-internet.de ↩1 ↩2
- Building Modernisation Act (GModG), Annex 7 — Maximum values of thermal transmittance for alterations to existing buildings (version 09/2026) gesetze-im-internet.de ↩1 ↩2
- Building Modernisation Act (GModG), § 84 — Recommendations for improving energy efficiency (version 09/2026) gesetze-im-internet.de ↩1 ↩2
- Building Modernisation Act (GModG), § 23 — Crediting of electricity from renewable energy (version 09/2026) gesetze-im-internet.de ↩
- co2online — Energy-efficient renovation: costs, benefits and funding, example and model calculation (as of 02/2026) co2online.de ↩
- BAFA — Federal funding for efficient buildings, individual measures on the building envelope (as of 07/2026) bafa.de ↩
This article reflects the position at the time of publication and does not replace legal or energy advice in an individual case. Binding are the Building Modernisation Act (Gebäudemodernisierungsgesetz, GModG) in its applicable version and the details in the issued energy performance certificate.