Efficiency house 85, 70, 55, 40: what the number means
Christine Werker Energieberaterin (EEE) & Architektin
As of:
“Efficiency house 55” (Effizienzhaus 55) sounds like a grade, but it is a statement of calculation — and it runs the opposite way to the letters in the energy performance certificate (Energieausweis): the smaller the number, the better the house. This article is written for owners who are considering a complete renovation and want to know which level is worthwhile.
The article first explains what the number is measured against, then which levels are still funded at all in 2026 and with what repayment grant (Tilgungszuschuss), and finally the difference from the energy efficiency class, which regularly causes confusion. Where the efficiency house renovation stands in the rest of the funding landscape is set out in Energy-efficient renovation and funding 2026.
What does the number after “efficiency house” mean?
- Efficiency house level (Effizienzhaus-Stufe)
-
The efficiency house level states the maximum percentage of the annual primary energy demand of a calculated reference building that a building may have. An efficiency house 55 therefore reaches at most 55 per cent of the demand of its reference building. The reference building has the same geometry, orientation and usable floor area as the real house, but the fixed technical specification of Annex 1 of the Building Modernisation Act (Gebäudemodernisierungsgesetz, GModG) — it is thus a calculated twin, not a show house.
It is not only primary energy demand that is checked. In addition there is a maximum value for the specific transmission heat loss, i.e. the amount of heat that escapes outwards per square metre of envelope area. Both values are calculated under building energy law in conjunction with DIN V 18599 and compared with the value of the reference building.23
| Level | Primary energy demand QP | Transmission heat loss H’T |
|---|---|---|
| Efficiency house 40 EE | 40% of QP,REF | 55% of H’T,REF |
| Efficiency house 55 EE | 55% | 70% |
| Efficiency house 70 EE | 70% | 85% |
| Efficiency house 85 EE | 85% | 100% |
| Efficiency house listed building EE | 160% | no requirement |
The number in the name is therefore the QP value, and the H’T value is in each case 15 percentage points above it. The listed building (Denkmal) is the exception: no envelope requirement, only the minimum building-physics values of DIN 4108-2 for the insulated building elements9 — and at 160 per cent it may even lie above the reference building.
It follows that: two houses at the same level can have very different consumption. The level is a ratio, not an absolute key figure — a large, compact building reaches it with different building elements from a small, jagged one.
Which levels are funded in 2026?
Since 21 July 2026, only levels with a class: every funded level carries either the renewable energy class (Erneuerbare-Energien-Klasse, EE) or the sustainability class (Nachhaltigkeitsklasse, NH). Levels without one of these classes are no longer funded.1
| Level | Repayment grant | Also possible |
|---|---|---|
| Efficiency house listed building EE | 5 per cent | NH class |
| Efficiency house 85 EE | 0 per cent | NH class |
| Efficiency house 70 EE | 0 per cent | NH class, WPB |
| Efficiency house 55 EE | 5 per cent | NH class, WPB, serial renovation |
| Efficiency house 40 EE | 10 per cent | NH class, WPB, serial renovation |
For levels 85 EE and 70 EE, the only remaining advantage is therefore the low-interest loan — there is no longer a repayment grant there. The maximum funding amount is uniformly 150,000 euros per residential unit.1
Three top-ups are added, and they can be combined with one another:1
- The sustainability class (NH) increases the percentage by 5 points. It is reached if a certificate under the quality seal “Nachhaltiges Gebäude PLUS” (sustainable building PLUS) is issued for the measure.
- The Worst Performing Building bonus brings 10 percentage points. This means a building that, because of the energy condition of its building elements, is among the worst in the German building stock. It applies from level 70 EE.
- The serial renovation bonus is staggered: 15 percentage points for levels 40 EE and 55 EE, five percentage points for level 70 EE.9 It requires prefabricated façade or roof elements to be installed whose degree of prefabrication significantly reduces the work on site.
Efficiency house 40 NH as a Worst Performing Building
An unrenovated detached house is brought up to efficiency house 40 level, with a sustainability certificate and recognised as a Worst Performing Building.
Base value efficiency house 40 EE: 10 per cent Sustainability class: + 5 percentage points Worst Performing Building: + 10 percentage points
Total: 25 per cent of the approved loan amount
With the full 150,000 euros drawn, that is 37,500 euros that do not have to be repaid. The figures follow the information sheet in the version of July 2026; above everything stands the cumulation limit of a 60 per cent funding rate from public funds.
Result 25 per cent repayment grant
Efficiency house level or energy efficiency class — what is the difference?
Both assess the same building and mean different things. The confusion regularly costs time in advisory meetings, because an “efficiency house 55” is read as “class 55”, which does not exist.
| Feature | Efficiency house level | Energy efficiency class |
|---|---|---|
| Appears in | funding approval and evidence | energy performance certificate |
| Reference | percentage of the reference building | fixed kilowatt-hour limits |
| Quantity | annual primary energy demand | final energy |
| Scale | 40, 55, 70, 85 — smaller is better | A+ to H — earlier in the alphabet is better |
| Basis | KfW programme conditions | § 86 and Annex 10 GModG |
| Determined by | energy efficiency expert | issuer of the energy performance certificate |
Under § 86 (2) of the Building Modernisation Act, the class follows directly from the final energy consumption or final energy demand;4 the limits are set out in Annex 10.5 The efficiency house level, by contrast, is a ratio of two calculated primary energy values. A house that reaches level 55 will as a rule end up in a good class — which letter exactly, only the energy performance certificate will tell. What is where in the certificate is shown in Energy performance certificate template: all five pages explained.
Who determines the level?
Not the tradesperson and not the bank, but an energy efficiency expert (Energieeffizienz-Experte) from the federal expert list.7 They develop the overall energy concept, produce the confirmation for the application and, after completion, confirm compliance with the technical minimum requirements as well as the savings achieved in primary and final energy and in carbon dioxide.1
The category counts too: for listed buildings and other building fabric particularly worthy of preservation, only experts in the category “Bundesförderung für effiziente Gebäude: Wohngebäude Denkmal” (Federal Funding for Efficient Buildings: residential listed buildings) are approved.1 Anyone who commissions the wrong expert only notices when the application comes back.
And a basic rule of the Act applies here too: § 89 (1) no. 4 ties the funding to the condition that the funded measure exceeds the statutory requirements.6 A renovation that merely meets the building element values of Annex 7 does not reach an efficiency house level and receives no money.
Frequently asked questions about efficiency house levels
What owners most often ask about efficiency house levels
Is an efficiency house 40 better than an efficiency house 85?
Yes. The number is the permitted share of the reference building’s primary energy demand — the smaller, the better. An efficiency house 40 may have at most 40 per cent of this demand, an efficiency house 85 at most 85 per cent.
Which efficiency house level corresponds to energy efficiency class A?
None, and the question cannot be answered. The level measures against an individually calculated reference building, the class against fixed kilowatt-hour limits. Only the energy performance certificate for your specific house gives the letter.
Is level 70 worthwhile if there is no repayment grant for it?
Only through the interest advantage of the loan and the bonus for a Worst Performing Building, which is granted from this level. Anyone who reaches that depth of renovation anyway should therefore check whether level 55 is within reach — that is where the repayment grant begins.
Do I need a heat pump for an efficiency house level?
Not necessarily a heat pump, but a share of at least 65 per cent of renewable energies or unavoidable waste heat in heating and cooling. That practically rules out a purely fossil supply, even though the law has permitted it again since 29 July 2026.
Does the level apply to the whole building or to the flat?
To the building. The basis for the loan amount, by contrast, is the number of residential units after renovation — for an apartment building the maximum amount multiplies accordingly.
Conclusion: the number is a ratio, not a consumption
An efficiency house level says how far your house stays below its calculated reference building — 55 means at most 55 per cent of its primary energy demand. Since July 2026, only levels with a renewable energy class or sustainability class are funded, and the repayment grant only begins at level 55. None of this has anything to do with the letter in the energy performance certificate: that depends on final energy and fixed limits, not on a comparison.
Sources
- KfW — Information sheet loan no. 261, BEG residential buildings loan efficiency house, valid from 21 July 2026 (as of 07/2026) kfw.de ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10
- KfW — Annex to information sheet loan no. 297/298/498, technical minimum requirements efficiency house 55 residential buildings (retrieved 09/2026) kfw.de ↩1 ↩2
- Building Modernisation Act (GModG), Annex 1 — Technical specification of the reference building (residential buildings) (version 09/2026) gesetze-im-internet.de ↩
- Building Modernisation Act (GModG), § 86 — Energy efficiency class of a residential building (version 09/2026) gesetze-im-internet.de ↩
- Building Modernisation Act (GModG), Annex 10 — Energy efficiency classes of residential buildings (version 09/2026) gesetze-im-internet.de ↩
- Building Modernisation Act (GModG), § 89 — Financial support (version 09/2026) gesetze-im-internet.de ↩
- Energy efficiency expert list for federal funding programmes (retrieved 09/2026) energie-effizienz-experten.de ↩
- KfW — Federal Funding for Efficient Buildings, residential buildings grant (461): “You can no longer apply for this grant” (retrieved 13 September 2026) kfw.de ↩
- BMWE — Guideline for the Federal Funding for Efficient Buildings, residential buildings (BEG WG), version of 20 July 2026, including the annex on technical minimum requirements energiewechsel.de ↩1 ↩2
This article reflects the position at the time of publication and does not replace legal or energy advice in an individual case. Binding are the Building Modernisation Act (Gebäudemodernisierungsgesetz, GModG) in its applicable version and the details in the issued energy performance certificate.