Available immediately Valid for 10 years Energy certificate under the GEG

Published on 7 min read Deutsch

Consumption or demand certificate

Energy performance certificate for a block of flats: one document, many tenancies

Christoph Werker

Energieberater & Geschäftsführer

As of:

You let a building with several flats — how often do you need the energy performance certificate? New for every new letting? Separately for each flat? This article is written for landlords of a block of flats (Mehrfamilienhaus) in single ownership; for owner-occupied flats in a condominium see energy performance certificate for an owner-occupied flat.

Multi-storey block of flats with a light rendered façade, pitched roof and balconies on a quiet street; on the left an energy performance certificate with a colour scale, from which orange lines lead to several flats. Heading in German: “Energieausweis fürs Mehrfamilienhaus – Ein Dokument, viele Mietverhältnisse” (energy certificate for a block of flats – one document, many tenancies).
One certificate for the whole building, yet every new letting is an occasion of its own: what landlords of a block of flats must present.

The article clarifies how many certificates a block of flats needs, when they fall due, which reference area applies, where the data comes from and what applies from five and from six flats. The overall picture is given in energy performance certificate: types, duty, costs and deadlines.

How many energy performance certificates does a block of flats need?

One. § 79 (2) sentence 1 is brief: an energy performance certificate (Energieausweis) is issued for a building.1 Not per flat, not per stairwell, not per tenancy agreement.

Sentence 2 names one exception:1 a separate certificate must be issued for parts of a building if they are to be treated separately under § 106 — for example a shop unit that differs substantially in type of use and building services and takes up a not insignificant share of the floor area.4 Two certificates then result.

For a purely residential block of flats it remains one document, valid for ten years from issue (§ 79 (3)).1

When is it due — on every new letting?

The occasion arises on every new letting, the certificate does not. § 80 (3) sentence 1 requires it “unless a valid energy performance certificate already exists for the building”.2 This half-sentence is the decisive one: a valid certificate covers all lettings in the building.

Something still has to be done on every new letting (§ 80 (5) in conjunction with (4)): present it at the latest at the viewing, hand it over after the contract is concluded — every time.2

Occasions in a block of flats and what they trigger
Event New certificate needed? What to do
New letting of a flat no, if a valid certificate exists present and hand over
Change of tenant in several flats no present and hand over for each tenancy
Sale of the entire building no, if valid present and hand over
Expiry of the ten years yes, on the next occasion have a new one issued
Conversion with an overall energy balance yes demand certificate under § 80 (2)

Which reference area applies — living space or usable floor area?

Usable floor area (Gebäudenutzfläche)

The usable floor area is the reference area to which the energy figure of a residential building is converted — not the living space (Wohnfläche). It also includes heated ancillary areas and is therefore regularly larger. If it is not known, it may be estimated under § 82 (2) of the Building Modernisation Act (Gebäudemodernisierungsgesetz): at 1.35 times the living space for up to two residential units with a heated basement, otherwise at 1.2 times.

The usable floor area, and for a block of flats that is more than a formality: the figure is stated in kilowatt-hours per square metre of usable floor area and year (§ 82 (2) sentence 1).3 If it is not known, it may be estimated — and the factors differ:

Estimating the usable floor area from the living space under § 82 (2) sentence 4 GModG
Building Factor
up to two residential units with a heated basement 1.35 × living space
other residential buildings, including the block of flats 1.2 × living space

The difference has a direct effect on the letter: the same number of kilowatt-hours over a larger area gives a smaller figure. Anyone who knows the actual usable floor area is better off stating it.

Two surcharges particularly often affect blocks of flats:3

  • Decentralised hot water preparation with unknown consumption: plus 20 kilowatt-hours per square metre of usable floor area and year (§ 82 (2) sentence 2). The classic case is the instantaneous water heater in every flat.
  • Cooled indoor air: surcharge of 6 kilowatt-hours per square metre of cooled usable floor area and year (sentence 3).

Where does the consumption data come from?

From the building itself — the quiet advantage of a block of flats. § 82 (4) no. 1 expressly names statements under the Heating Costs Ordinance (Heizkostenverordnung) for the entire building as the data basis.37 Anyone who bills according to consumption has them anyway.

Three rules apply:3

  • Statements from a continuous period of 36 months, the most recent period of which is no more than 18 months ago.
  • Longer vacancies must be taken into account appropriately in the calculation — regularly an issue where tenants change often.
  • What counts is the average over the period.

What counts is the consumption of the entire building. Across all units and three years, occupant behaviour largely evens out — which makes the consumption certificate (Verbrauchsausweis) more meaningful for a block of flats than for a single-family house.

What applies from five and from six flats?

Two thresholds that have nothing to do with each other and are often confused.

From five flats the demand certificate requirement no longer applies. Under § 80 (3) sentence 2 it applies only to residential buildings with fewer than five flats and a building application before 1 November 1977.2 An older building with six flats has the choice, a two-family house from 1960 does not — details in consumption or demand certificate.

From six flats operating duties are added. Water-based heating systems installed before 1 October 2009 must be inspected and optimised by 30 September 2027 (§ 60b (1));5 after a new heating system is installed, hydraulic balancing must be carried out (§ 60c (1)).6 This has nothing to do with the law on certificates — but in practice it does, because both reduce the consumption that will appear in the certificate three years later.

What changes on 1 January 2027

Three points directly affect the block of flats.9

Extending a contract becomes an occasion. § 80 (3) sentence 1 of the new version expressly also names the extension of a tenancy, lease or leasing contract. Until now only a new contract triggers the duties — anyone with graduated-rent or fixed-term tenancy agreements will therefore have considerably more occasions.

The duty to display no longer covers residential buildings. The new subsections 6 and 7 are directed only at non-residential buildings with heavy public traffic, without area thresholds. For a purely residential block of flats there is none from 2027.

The consumption certificate is redrafted. Only for buildings used exclusively for residential purposes; recording over two years, hot water flat rate 16 kilowatt-hours, reference quantity net floor area (Nutzfläche).

What belongs in the advertisement for a single flat?

The same five details as for the whole building, because they come from the building’s certificate: certificate type, final energy demand or consumption, main energy sources, year of construction and energy efficiency class (§ 87 (1)).8

This regularly causes irritation: the attic flat carries the same figure as the ground-floor flat, even though it has more area facing outside. That is correct — the certificate rates the building. Even so, the details may not be omitted.

Frequently asked questions about blocks of flats

What landlords of a block of flats ask most often

Do I need a separate energy performance certificate for each flat?

No. § 79 (2) GModG issues the certificate for the building. A separate certificate for part of a building only arises if that part is to be treated separately under § 106 — for example a shop unit with its own building services.

Do I have to have a new certificate issued for every new letting?

No, as long as the existing one is valid. But you must present it at every viewing and hand it over after every contract is concluded — the duty to act repeats itself, the duty to issue does not.

Which area counts for the figure?

The usable floor area. If it is unknown, for a block of flats it is set at 1.2 times the living space — whereas for buildings with up to two residential units and a heated basement it is 1.35 times.

What if every flat has its own instantaneous water heater?

If the consumption attributable to hot water is not known, the final energy consumption is increased by a flat 20 kilowatt-hours per square metre of usable floor area and year. Anyone who knows the values should supply them — the flat rate is conservative.

Does the demand certificate requirement for old buildings also apply with six flats?

No. It applies only to residential buildings with fewer than five flats and a building application before 1 November 1977. From five flats there is a choice between both certificate types.

Conclusion: one certificate, many duties to present

The block of flats receives one energy performance certificate for ten years, and it covers every letting during that period. What has to be repeated is not the issuing but the presenting and handing over. The stumbling blocks lie elsewhere: in the reference area with its factor of 1.2, in the hot water surcharge and in the vacancy correction — and from 2027 in the contract extension.

Sources

  1. Building Modernisation Act (GModG), § 79 — Principles of the energy performance certificate (version 09/2026) gesetze-im-internet.de ↩1 ↩2 ↩3 ↩4
  2. Building Modernisation Act (GModG), § 80 — Issuing and use of energy performance certificates (version 09/2026) gesetze-im-internet.de ↩1 ↩2 ↩3 ↩4
  3. Building Modernisation Act (GModG), § 82 — Energy consumption certificate (version 09/2026) gesetze-im-internet.de ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
  4. Building Modernisation Act (GModG), § 106 — Mixed-use buildings (version 09/2026) gesetze-im-internet.de ↩
  5. Building Modernisation Act (GModG), § 60b — Inspection and optimisation of heating systems (version 09/2026) gesetze-im-internet.de ↩1 ↩2
  6. Building Modernisation Act (GModG), § 60c — Hydraulic balancing (version 09/2026) gesetze-im-internet.de ↩1 ↩2
  7. Heating Costs Ordinance (Verordnung über Heizkostenabrechnung, HeizkostenV), version as promulgated (as of 09/2026) gesetze-im-internet.de ↩
  8. Building Modernisation Act (GModG), § 87 — Mandatory details in a property advertisement (version 09/2026) gesetze-im-internet.de ↩
  9. Act amending the Building Energy Act and further provisions in the heating sector, Federal Law Gazette 2026 I No. 226 of 28 July 2026 (Article 2, in force from 01.01.2027) recht.bund.de ↩1 ↩2

This article reflects the position at the time of publication and does not replace legal or energy advice in an individual case. Binding are the Building Modernisation Act (Gebäudemodernisierungsgesetz, GModG) in its applicable version and the details in the issued energy performance certificate.